标准摘要
[中文适用范围]: IEC 60700 的这一部分适用于在阀岛@之间直接连接金属氧化物避雷器的晶闸管阀,用于高压直流电力传输的线路换向转换器或作为背靠背链路的一部分。它仅限于电气类型和生产测试。本标准规定的试验基于空气绝缘阀门。对于其他类型的阀门@,可以商定测试要求和验收标准。 [外文原描述]: IEC 60700-1:2015 applies to thyristor valves with metal oxide surge arresters directly connected between the valve terminals, for use in a line commutated converter for high voltage d.c. power transmission or as part of a back-to-back link. It is restricted to electrical type and production tests. The tests specified in this standard are based on air insulated valves. For other types of valves, the test requirements and acceptance criteria can be agreed. This edition includes the following significant technical changes with respect to the previous edition. a) Definitions of terms "redundant thyristor levels", "thyristor level", "valve section" have been changed for clarification. b) The notes were added to test requirements of dielectric d.c. voltage tests for valve support, MVU, valve, specifying that before repeating the test with opposite polarity, the tested object may be short-circuited and earthed for several hours. The same procedure may be followed at the end of the d.c. voltage test. c) Table 1 on thyristor level faults permitted during type tests was supplemented. d) The alternative MVU dielectric test method was added. e) It was specified that production tests may include routine tests as well as sample tests. f) It was added into test requirements for periodic firing and extinction tests that a scaling factor for tests shall be applied when testing with valve sections. The contents of the corrigendum of January 2017 have been included in this copy.
英文名称Thyristor valves for high voltage direct current (HVDC) power transmission - Part 1: Electrical testing