标准摘要
[中文适用范围]: 本部分 IEC/IEEE 80005 描述了高压岸电连接 (HVSC) 系统,包括船载和岸基系统,用于从岸上向船舶供电。 本文件适用于 HVSC 系统的设计、安装和测试,涉及 - 高压岸电配电系统, - 岸到船连接和接口设备, - 变压器/电抗器, - 半导体/旋转频率转换器, - 船舶配电系统,以及 - 控制、监控、联锁和电源管理系统。 不适用于停泊期间的电力供应,例如干船坞和其他停运维护和修理。 国家行政机构或船舶运营管辖范围内的当局和/或负责岸电供应或配电系统的所有者或当局可以施加额外和/或替代要求。 预计 HVSC 系统适用于需要 1 MVA 或以上或具有高压主电源的船舶。 本文件不涵盖低压岸电连接系统。 [外文原描述]: IEC/IEEE 80005-1:2019+AMD1:2022+AMD2:2023 describes high-voltage shore connection (HVSC) systems, onboard the ship and on shore, to supply the ship with electrical power from shore. This document is applicable to the design, installation and testing of HVSC systems and addresses: - HV shore distribution systems, - shore-to-ship connection and interface equipment, - transformers/reactors, - semiconductor/rotating frequency convertors, - ship distribution systems, and - control, monitoring, interlocking and power management systems. It does not apply to the electrical power supply during docking periods, for example dry docking and other out of service maintenance and repair. Additional and/or alternative requirements can be imposed by national administrations or the authorities within whose jurisdiction the ship is intended to operate and/or by the owners or authorities responsible for a shore supply or distribution system. It is expected that HVSC systems will have practicable applications for ships requiring 1 MVA or more or ships with HV main supply. Low-voltage shore connection systems are not covered by this document. This second edition cancels and replaces the first edition published in 2012. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) modification of 4.1, Figure 1: transformer on ship is optional, earthing switches on ship removed; b) 4.2.2 and new item 11.3: alternative procedure of periodic testing added; c) modification of 4.9: - minimum current value in the safety circuits shall be 50 mA; - opening of safety loop shall cause the automatic opening of ship and shore HVSC circuit breakers in a maximum time of 200 ms; d) modification of 5.2: added Figure on harmonic contents; e) modification of 6.2.3: – earthing transformer with resistor can be used also on the secondary side; – neutral earthing resistor rating in amperes shall be minimum 25 A, 5 s; f) modification of all annexes: the safety circuits shall be mandatory; g) modification of A.2.1: a metallic shield shall be installed at least on the power cores or common on pilot wires; h) modification of B.7.2.1: new safety circuit introduced: single line diagram and description; i) modification of C.4.1: SLD for cruise ships was updated, also the safety circuits to be coherent with main body, IEC symbols and introduced more details about the control socket-outlets and plugs manufacturer type; j) modification of C.7.3.1: - shore power connector pin assignment is updated; - all cruise ships shall use 4 cables in all cases; k) added D.6.1: the supply point on shore can be fixed or movable; l) modification of D.7.3.2: the voltage used in the pilot circuit for container ships shall be less than 60 V DC or 25 V AC. m) added D.8.6 and D.9.3.1: automatic restart and synchronization alternatives; n) Annex E set to informative; o) Annex F set to informative.
英文名称Utility connections in port - Part 1: High voltage shore connection (HVSC) systems - General requirements