标准摘要
[中文适用范围]: 本文件规定了一种将在各种比例和非比例标距上获得的断裂后室温百分比伸长率转换为其他标距长度的方法。 当应用于拉伸强度范围为 450 至 750 N/mm2 且处于固溶处理条件下的奥氏体不锈钢时,转换所依据的公式 (1) 被认为是可靠的。 这些换算不适用于: a) 冷轧钢; b) 调质钢; c) 非奥氏体钢。 当标距长度超过 250 S 或试件的宽厚比超过 20 时,这些换算不适用。 [外文原描述]: This document specifies a method of converting room temperature percentage elongations after fracture obtained on various proportional and non-proportional gauge lengths to other gauge lengths. Formula (1), on which conversions are based, is considered to be reliable when applied to austenitic stainless steels within the tensile strength range 450 to 750 N/mm 2 and in the solution treated condition. These conversions are not applicable to: a) cold reduced steels; b) quenched and tempered steels; c) non-austenitic steels. These conversions are not applicable when the gauge length exceeds 25√ S 0 or where the width to thickness ratio of the test piece exceeds 20.
英文名称Steel — Conversion of elongation values — Part 2: Austenitic steels