标准摘要
[中文适用范围]: 本文件规定了空气冷却式空调器和空气 - 空气热泵的性能测试、标准条件和测试方法,用于确定容量和效率等级。本文件适用于以下设备:不风管式空气冷却式空调器和不风管式空气 - 空气热泵;或容量小于 8 kW 且设计用于外部静压小于 25 Pa 的风管式空调器和/或风管式热泵。本文件仅限于:住宅、商业和工业用单 package 和分体式空调器和热泵;工厂制造、电力驱动并使用机械压缩的设备;使用单级、多级和可变容量组件的多分体式系统(利用一个或多个制冷系统,一个室外单元和一个或多个室内单元,由单个恒温器/控制器控制)。本文件中的测试和评级要求基于匹配组件的使用。本文件不适用于以下设备的评级和测试:a) 水源热泵或水冷却式空调器;b) 多分体式系统空调器和空气 - 空气热泵(对此类设备的测试应遵循 ISO 15042);c) 带有冷凝器排气风管的移动(无窗)单元;d) 不构成完整制冷系统的独立组件;e) 使用吸收式制冷循环的设备;f) 风管式设备,除非本条款另有规定(对此类设备的测试应遵循 ISO 13253)。本文件不包括季节性效率的确定,这在某些国家可能需要,因为它们能更好地指示实际运行条件下的效率。注: throughout this document, the terms "equipment" and "systems" mean "air conditioners" and/or "heat pumps".( Throughout this document, 本文件中的术语“设备”和“系统”是指“空调器”和/或“热泵”。) [外文原描述]: ISO 5151:2017 specifies performance testing, the standard conditions and the test methods for determining the capacity and efficiency ratings of air-cooled air conditioners and air-to-air heat pumps. ISO 5151:2017 is applicable to the following equipment: - non-ducted air-cooled air conditioners and non-ducted air-to-air heat pumps; or - ducted air conditioners and/or ducted heat pumps rated at less than 8 kW and intended to operate at an external static pressure of less than 25 Pa. ISO 5151:2017 is limited to: - residential, commercial and industrial single-package and split-system air conditioners and heat pumps; - factory-made, electrically driven and use mechanical compression; - utilizing single, multiple and variable capacity components; - multiple split-system utilizing one or more refrigeration systems, one outdoor unit and one or more indoor units, controlled by a single thermostat/controller. The requirements of testing and rating contained in this document are based on the use of matched assemblies. ISO 5151:2017 is not applicable to the rating and testing of the following: a) water-source heat pumps or water cooled air conditioners; b) multi-split-system air conditioners and air-to-air heat pumps (follow ISO 15042 for the testing of such equipment); c) mobile (windowless) units having a condenser exhaust duct; d) individual assemblies not constituting a complete refrigeration system; e) equipment using the absorption refrigeration cycle; f) ducted equipment except for those specified in this clause (follow ISO 13253 for the testing of such equipment). ISO 5151:2017 does not cover the determination of seasonal efficiencies, which can be required in some countries because they provide a better indication of efficiency under actual operating conditions. NOTE Throughout this document, the terms "equipment" and "systems" mean "air conditioners" and/or "heat pumps".
英文名称Non-ducted air conditioners and heat pumps — Testing and rating for performance